MODEL II SPILL VALVE
MAINTENANCE
1. Lift up and then rotate the two Spring Plunger handles to lock the Spring Plungers in the up position.
2. Now, pull the Seal Plate Arm out of its retaining slots as shown. |
REPLACING THE SEAL AND SEAL SHIELD
| Model II* Owner Replaceable Seals: | Viton | Part #EP05-A216B - White Markings | ||||||
| *Model II seals can be used on | EPDM | Part #EP05-A216A - Yellow Markings | ||||||
| Model I Spill Valves | Butyl | Part #EP05-A216C - Red Markings | ||||||
| Teflon™ Seal Shield | Part #E03-SEAL-SHIELD |
1. Remove the Weather Cover. Open valve and remove Seal Plate.
2. Study the drawings below which show the shape and fit of the Teflon™ Seal Shield to the Seal.